Fully C E approved for most European countries.
80% Energy efficient
Special adaptor provided for PVC plumbing
Unitherm governor - eliminates condensation and scale
Easy to service and maintain
Resistant to wind & downdrafts
Can be installed indoors and outdoors
High wind tops for the 185, 265 and 405 models are available on request
Water Balance Important - If you do not pay due regard to 'water balance' and regularly test your pool water with a good quality water testing set, then you may suffer a damaged Heat Exchanger inside or outside your boiler, either through clogging up (excessive scaling) or corrosion by too much acid.
Operating Through The Winter Due to condensation, boilers required to operate throughout the winter should not be installed outdoors.
Ventilation Requirements The heater must have both ventilation and combustion air.
To size the heater required for an Outdoor Pool (with Solar Cover) the calculation is: 10 BTU per gallon.
To size the heater required for an Indoor Pool the calculation is: 6 BTU per gallon.
Should you wish to discuss this further with one of our heating experts please call us on 0117 230 9660.